Package Oil-Free BEBICON

V-Type

Lubrication style Oil Less(Dry)
Motor output(kW) 5.5 7.5 11 15
Model POD-5.5VB POD-7.5VB POD-11VB POD-15V
Maximum Discharge Pressure(MPa) 0.93 0.85
Capacity @ Initial setting(L/min) 625 @ 0.83MPa 905 @ 0.75MPa 1,325 @ 0.75MPa 1,750@0.75MPa
Range of discharge pressure setting(MPa) 0.60-0.88 0.60-0.80
Discharge air dew point (degree C) less than 15 less than 10
Motor start stystem Inverter
Pressure Indication Digital gauge(LED)
Air Outlet 1/2B(15A)provided with stop value(rubber hose ID:12mm) 1B(25A)provided with stop value
Air Tank Capacity(L) 32
Required minimum air tank capacity(L)(option) 150 230
External dimensions Width × Depth × height(mm) 961×816×1,492 945×816×1,492 1,445×975×1,463 1,682×975×1,463
Weight(kg) 329 371 536 591
Noise level dB[A] 58 59 62 66
*1
Use the compressor at a place where ambient temperature is 5°C to 40°C.
*2
The noise levels shown are those obtained at a distance of 1.5 m from the front of the compressor operating under full load in a reverberation-free foom.

*3
When the air dyer is operated at the same time, the noise level becomes 1 to 2 dB higher than the value shown.
*4
The amount of air discharged form the air dryer is about 3% to 5% smaller than the amount of air discharged form the compressor due to the precipitation of drain.

*5
Package Oil-Free BEBICON is unavailable in Singapore, Malaysia and China due to their pressure vessel regulations.
*6
If air demand is small, capacity is Decreased up to 40% form above specified value, when constant-pressure control is selected. If tank pressure is increased even the 40% of full load, motor stops running at maximum discharge pressure.

*7
When the air dyer is operated at the same time, the noise level becomes 1 to 2 dB higher than the value shown.
*8
V-type compressor requires additional air tank whose volume is bigger than above specified value.

Conventional Type

Without Dryer Model

Series Name Pressure switch type M-Type
Motor output(kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Model PO-0.75PGS5/6 PO-0.75PG5/6 PO- 1.5M5/6 PO- 2.2M5/6 PO- 3.7M5/6 PO-5.5MA5/6 PO-7.5MA5/6 PO-11MA5/6 PO-15M5/6
Maximum Discharge Pressure(MPa) 0.93 0.85
On-off controlpressure (MPa) 0.78-0.93 0.70-0.85
Compressed air output(L/min) 75 165 240 405 605 875 1,280 1,700
Outlet air dew point(°C) Without air dryer
Motor start system Full-voltage start Full-voltage start(with restart load reducing device)
Control method Pressure switch Semiconductor + microcomputer
Air Outlet 1/4B(8A)
provided with stop valve
3/8B(10A)
provided with stop valve
1/2B(15A)
provided with stop valve
1B(25A)
provided with stop valve
Air tank capacity 30 5 32
External dimentions
Width × Depth × height(mm)
707×537×911 854×594×947 854×644×947 932×720×999 1,008×816×1,215 1,175×975×1,463 1,176×975×1,463
Weight (kg) 111 103 110 123 168 278 309 444 470
Noise level dB[A] 52 55 57 58 59 62 66

Dryer built-in Model

Series Name Pressure switch type  M-Type
Motor output(kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15
Model POD-0.75PSF5/6 POD-0.75PF5/6 POD-1.5M5/6 POD-2.2M5/6 POD-3.7M5/6 POD-5.5MA5/6 POD-7.5MA5/6 POD-11MA5/6 POD-15M5/6
Maximum Discharge Pressure(MPa) 0.93 0.85
On-off controlpressure (MPa) 0.78-0.93 0.70-0.85
Compressed air output(L/min) 75 165 240 405 605 875 1,280 1,700
Outlet air dew point(°C) less than 10 less than 15 less than 10
Motor start system Full-voltage start Full-voltage start(with restart load reducing device)
Control method Pressure switch Semiconductor + microcomputer
Air Outlet 1/4B(8A)
provided with stop valve
3/8B(10A)
provided with stop valve
1/2B(15A)
provided with stop valve
1B(25A)
provided with stop valve
Air tank capacity 30 5 32
External dimentions
Width × Depth × height(mm)
716×537×1,140 854×594×947 854×644×947 940×720×999 961×816×1,492 945×816×1,492 1,445×975×1,463 1,483×975×1,463
Weight (kg) 133 125 131 144 197 317 358 519 560
Noise level dB[A] 52 55 57 58 59 62 66
*1
Use the compressor at a place where ambient temperature is 0°C(5°C for the type with built-in air dryer) to 40°C.
*2
The noise levels shown are those obtained at a distance of 1.5 m form the fornt of the compressor operating under full load in a reverberation-free room.

*3
When the air dryer is operated at the same time, the noise level become 1 to 2 dB higher than the value shown.
*4
The out of compressed air the amount of air discharged under the maximum pressure converted in terms of air suction (under the atmospheric pressure).

*5
The amount of air discharge from the air dryer is about 3% to 5% smaller than the amount of air discharged from the compressor due to the precipitsation of drain.

*6
Package Oil-Free BEBICON is unavailable in Singapore, Malaysia and China due to their pressure vessel regulations.
*7
15kW compressor requires additional air tank whose volume is bigger than 230L.